Provide weighing solutions

Customized for your unique needs.

BC3 Load Cell


Classification:

● Nickel plated alloy steel IP68 column shear load cell ● Hermetically sealed ● Suitable for truck, track, hopper and other electronic weighing devices ● High accuracy ● Protected against lightning surges ● Current calibrated (sc option)

●FEATURES

● Nickel plated alloy steel IP68 column shear load cell
● Hermetically sealed

● Suitable for truck, track, hopper and other electronic weighing devices
● High accuracy

● Protected against lightning surges
● Current calibrated (sc option)

 

TECHNICAL INDEX    
Accuracy class   C3
Output sensitivity (=FS) mV/N 1.5±0.004
Maximum capacity (Emax) t 10/20/25/30/50
Maximum number of load cell intervals (nLC)   3000
Ratio of minimum LC verification interval Y=Emax / Vmin   7500
Combined error %FS ±0.023
Minimum dead load t 0
Safe overload %FS 150
Ultimate overload %FS 300
Zero balance  %FS +1.0
Excitation, recommended voltage V 5~12(DC)
Excitation maximum V 18(DC)
Input resistance 700±4
Output resistance 703±4
Insulation resistance MΩ ≥5000(50VDC)
Compensated temperature °C -10~+40

 

DIMENSIONS IN MM

 

WIRING

• Shielded, 6 conductor cable.
• Cable diameter: Φ6.3mm.
• Standard cable length: 13m.
• Shield is not connected to element.